Form factor
Contents |
[edit] General
Form factor, it could be said in general is a mathematical way to compare two different variables of an object by ratios. It is commonly used in the electronic hardware industry ascwell as the design and construction industry.
[edit] Electronics
In electronics form factor might be used in different ways to describe the size, shape, and specification of various pieces of hardware or components such as motherboards, USB and disc drives or memory cards.
[edit] Buildings
In the design and construction of buildings, form factor is a simplified way of measuring the efficiency of a buildings' shape, by means of a ratio between the external surface area (SA) and the internal treated floor area (TFA). This is specifically useful when it comes to heating, because the TFA is the floor area to be heated and the SA is the surface through which the heat will gradually be lost. The lower the ratio between the two the slower will be the heat loss for the same level of fabric performance.
Lower heat loss factors ( or ratios) of between 0.7 and 2.0 will be found with simple medium to high rise buildings whilst higher factors from 2.0 up to 5.0 will be found wih lower rise and single detatched dwellings as these have a greater surface area that is exposed to the outside.
[edit] Passivhaus
Form factor has gained interest, partly because it is a fundamental element of the internationally recognised passivhaus standard. This is a design and construction standard for passive buildings which targets achieving thermal comfort only by the heat generated by the occupants ( or minimal heating) , it does so though super insulation, minimising thermal bridges, airtightness, triple glazed openings, and ventilation systems with heat recovery.
[edit] Detail
Form factor is a simplification tool and designers should be aware that there are some complexities in the different ways certain variables are calculated when it comes to the detail. For example in the passivhaus air tightness test (n50) the treated floor area used to calculate the internal volume excludes any internal walls and floors. In the infiltration air change rate used for ATTMA & Buildings Regulations, it is the number of cubic meters of air leakage per hour per metre 2 of the envelope that is of concern. As such intermal walls and floors are included as within the total internal volume as the variable considered. ith Passive hoause being measured as ≤ 0.6 h-1@ 50 Pa. and ATTMA as m3/hr/m2@50Pa (q50).
for further information visit the passivhaustrust or the ATTMA.
[edit] Related articles on Designing Buildings
Featured articles and news
CIOB launches global mental health survey
To address the silent mental health crisis in construction.
New categories in sustainability, health and safety, and emerging talent.
Key takeaways from the BSRIA Briefing 2024
Not just waiting for Net Zero, but driving it.
The ISO answer to what is a digital twin
Talking about digital twins in a more consistent manner.
Top tips and risks to look out for.
New Code of Practice for fire and escape door hardware
Published by GAI and DHF.
Retrofit of Buildings, a CIOB Technical Publication
Pertinent technical issues, retrofit measures and the roles involved.
New alliance will tackle skills shortage in greater Manchester
The pioneering Electrotechnical Training and Careers Alliance.
Drone data at the edge: three steps to better AI insights
Offering greater accuracy and quicker access to insights.
From fit-out to higher-risk buildings.
Heritage conservation in Calgary
The triple bottom line.
College of West Anglia apprentice wins SkillELECTRIC gold.
Scottish government launch delivery plan
To strengthen planning and tackle the housing emergency.
How people react in ways which tend to restore their comfort.
Comfort is a crucial missing piece of the puzzle.
ECA launches Recharging Electrical Skills Charter in Wales
Best solutions for the industry and electrical skills in Wales.
New homebuilding skills hub launch and industry response
Working with CITB and NHBC to launch fast track training.
Comments
The definition of form factor shown in this article is incorrect. The form factor relating to heat loss is the ratio of the total heat loss envelop area to the total heated floor area (not the other way round as described in the article).
Thankyou, I believe you are correct, as we are a wiki please feel free to edit the page yourself and we will review also but thankyou for the comment. Best the editor.